TM 9-2320-302-20-2
ANTI-LOCK BRAKE SYSTEM (ABS) FLOOR WIRING HARNESS REPLACEMENT
(M915A3 NEW MODEL, M916A3, M917A2) - CONTINUED
0128 00
INSTALLATION - CONTINUED
7.
Install fuse panel cover (WP 0084 00).
8.
Connect three connectors (6) of ABS floor wiring harness (7) to connectors (5) of ABS ECU wiring harness (8).
5
6
7
6
8
5
9.
Install plastic cover (1) to plate (2) with two washers (4) and screws (3).
1
3,4
2
END OF WORK PACKAGE