TM 9-2320-302-20-2
BATTERY EQUALIZER REPLACEMENT - CONTINUED
0071 00
REMOVAL - CONTINUED
14
1
22
19,20,21
15
16,17,18
INSTALLATION
NOTE
Perform steps 1 and 2, only if bracket was removed.
1.
Install equalizer bracket (22) to battery box (14) with four washers (20), two bolts (21), and two new locknuts (19).
2.
Install batteries (WP 0143 00).
NOTE
Replacement battery equalizer comes with new mounting hardware for cable connections at GND, 12V, and
24V terminals.
3.
Position screws (4, 7, and 10) at 24V, 12V, and GND equalizer terminals. Install battery equalizer (1) and cable bracket
(15) to battery box (14) and equalizer bracket (21) with six screws (18), 12 washers (17), and six new locknuts (16).
4.
Loosely install two cables (13), lockwasher (3), and nut (2) to screw (4) at 24V terminal of battery equalizer (1).
5.
Loosely install two cables (12), lockwasher (6), and nut (5) to screw (7) at 12V terminal.
6.
Loosely install ground cable (11), lockwasher (9), and nut (8) to screw (10) at ground (GND) terminal.
7.
Tighten nuts (2, 5, and 8) to 110 lb-in (12.4 Nm).
0071 00-3
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |