TM 9-2320-302-20-2
BATTERY EQUALIZER REPLACEMENT - CONTINUED
0071 00
REMOVAL
NOTE
Tag cables to aid in installation.
1.
Underneath battery box (14), remove nut (8), lockwasher (9), ground cable (11), and screw (10) from ground (GND) ter-
minal of battery equalizer (1).
2.
Remove nut (5), lockwasher (6), two cables (12), and screw (7) from 12V terminal.
3.
Remove nut (2), lockwasher (3), two cables (13), and screw (4) from 24V terminal.
1
2,3,4
14
5,6,7
13
8,9,10
12
11
4.
Remove six locknuts (16), 12 washers (17), six screws (18), cable bracket (15), and battery equalizer (1) from equalizer
bracket (21) and battery box (14). Discard locknuts.
NOTE
Perform steps 5 and 6, only if bracket is damaged.
5.
Remove batteries (WP 0143 00).
6.
Remove two locknuts (19), four washers (20), two bolts (21), and equalizer bracket (22) from battery box (14). Discard
locknuts.