AUTOMATIC ETHER STARTING AID MAINTENANCE - CONTINUED
0039 00
AUTOMATIC STARTING AID INSTALLATION - CONTINUED
7.
Install atomizer (4) on intake manifold.
8.
Connect ether tube (3) to atomizer (4).
9.
Connect ether tube (3) to fitting (22).
10.
Connect ether control relay harness connector (14) to main harness connector (15).
11.
Connect harness connector (21) to main harness connector (16).
12.
Turn on ignition (TM 9-2320-302-10).
13.
Red indicator light (8) on ether control relay (13) should be ON.
14.
Run a magnet over plate (9) on ether control relay (13). Red indicator light (8) should go OFF.
FUEL CYLINDER INSTALLATION
CAUTION
Always use new gasket when replacing fuel cylinder. Using an old or worn gasket can cause solenoid to dis-
charge entire contents of cylinder into intake manifold. Failure to follow this caution can result in severe
engine damage.
NOTE
Replacement fuel cylinder comes with a new gasket.
1.
Apply thin coat of lubricating oil to new gasket (27) and threads of new fuel cylinder (1).
2.
Install gasket (27) and fuel cylinder (1) to valve (25). Tighten clamp (26).
3.
Turn on ignition (TM 9-2320-302-10).
4.
Red indicator light (8) on ether control relay (13) should be ON.
5.
Run a magnet over plate (9) on ether control relay (13). Red indicator light (8) should go OFF.
0039 00-4