TM 9-2320-302-20-2
OIL SAMPLE VALVES REPLACEMENT
THIS WORK PACKAGE COVERS
Removal, Installation
INITIAL SETUP
Materials/Parts
Tools and Special Tools
Tool kit, general mechanic's (Item 50, WP 0306 00)
Nut, self-locking (P/N M45913/1-8CG5C))
Compound, sealing, pipe (Item 13, WP 0305 00)
NOTE
Engine and transmission oil sample valves are replaced the same way. Engine oil sample valve is illustrated.
REMOVAL
1.
Disconnect hose (8) from connector (9).
2.
Remove connector (9) and bushing (10) from oil cooler.
3.
Remove hose (8) from adapter (1).
4.
Remove adapter (1) and sample valve (3) from bracket (2).
5.
Remove locknut (4), washer (5), screw (7), washer (6), and bracket (2) from mounting bracket (11). Discard locknut.
1
2
3
11
4
7
5
8
6
9
10
342-121
|