ENGINE OIL FILTERS MAINTENANCE (M915A3 NEW MODEL, M916A3, M917A2) - CONTINUED
0027 00
ELEMENT REMOVAL - CONTINUED
4
2
5
6
7
9
3
8
1
CLEANING
WARNING
Compressed air used for cleaning or drying purposes, or for clearing restrictions, should never
exceed 30 psi (207 kPa). Wear protective clothing (goggles/shield, gloves, etc.) and use cau-
tion to avoid injury to personnel.
1.
Using detergent, clean filter elements, drain plugs, bottom caps, springs, and o-rings. Use a soft brush as necessary.
2.
Dry components using rags and compressed air. Dry filter elements by directing compressed air from INSIDE filter ele-
ment.
0027 00-3