Air vents are located on thermostat housing and on upper front of oil cooler.
Fill the system with a mixture of clean water and ethylene glycol base permanent type anti-
freeze (Check with Organizational Maintenance for the proper mixture of water and anti-
freeze).
a. CLOSE ENGINE BLOCK AND RADIATOR DRAINCOCKS AND OPEN COOLING
SYSTEM AIR VENT.
b. POUR COOLANT INTO RADIATOR FILLER NECK UNTIL SIGHT GLASS IS FULL.
c . START ENGINE AND ALLOW IT TO REACH NORMAL OPERATING TEMPERA-
TURE (165F195F).
d. RECHECK COOLANT LEVEL.
PUT ON RADIATOR CAP.
e.
f.
CHECK FOR LEAKS.
WARNING
Let radiator cool before removing cap. Remove radiator
cap in two steps. First, place a thick cloth over the cap and
slowly rotate cap left to its first stop; pause, and let pres-
sure escape from cooling system. Then rotate cap farther
left until you can remove it. Failure to follow this procedure
can result in serious burns.