TM 9-2320-270-10
Troubleshooting - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
PUSHER AXLE
PUSHER AXLE WILL NOT COME UP
Step 1. Check amount of air pressure shown on AIR PRESS gage (2).
a. If air pressure is not at least 65 psi (448 kPa), wait until pres-
sure builds. Low AIR pressure warning light (3) and buzzer
should turn off when there is enough air pressure.
Step 2.
b. If air pressure does not build to 65 psi (448 kPa) go to LOW
AIR PRESSURE (warning light and buzzer on) page 3-25.
Check position of PUSHER AXLE air pressure load control (4) and raise/
lower control (5).
a. Move PUSHER AXLE air pressure load control (4) fully to
DEFLATE position and raise/lower control (5) fully to
LIFT UP position.
b. If pusher axle still will not come up, notify Organizational
Maintenance.
END OF PROCEDURE
TA220918