TM 5-2420-224-34
HAMMER
DRILL
REPAIR
(CONT)
10. INSTALL new quad RING (24), new backup ring (25), and new GASKET (26) on housing (27).
11. INSTALL two new PACKINGS (28) and two pins (29) in housing (13).
12. INSTALL HOUSING (27), two socket head capscrews (30), and setscrew (31) on housing (13).
TIGHTEN CAPSCREWS to 60 Ib-ft (81 N.m).
NOTE
Lever must be installed with narrow portion toward handles, and setscrew must be
seated in hole of valve.
13. INSTALL two pins (32), VALVE (33), new packing (34), spacer ring (35), retaining ring (36), lever (37),
and setscrew (38).
14. INSTALL pin (39), PLUG (40), and setscrew (41).
15. INSTALL new cup SEAL (42) with lips facing inward, washer (43), new cup SEAL (44) with lips facing
outward, and new packing (45).
16. INSTALL new backup RING (46) and new PACKING (47) on flow sleeve tube (48).