HYDRAULIC OIL COOLER REPAIR (CONT)
CAUTION
Support oil cooler to prevent
damage to fins.
2.
INSTALL oil COOLER (3) in housing (4).
INSTALL six SCREWS (5) and six new lock
3.
washers (6).
4.
I N S T A L L HOUSING (7), screw (8), and
washer (9).
5.
INSTALL four SCREWS (10).
INSTALL PLATE (11), 12 washers (12). 12
6.
new lock washers (13), and 12 screws (14).
INSTALL TERMINAL (15) and two screws
7.
(16).
INSTALL FAN IMPELLER (TM 5-2420-224-
8.
20).
NOTE
Follow-on Maintenance:
Install hydraulic oil cooler thermal
switches (TM 5-2420-224-20).
Install hydraulic oil cooler (TM 5-
2420-224-20).