TM
5-2420-224-34
BACKHOE CONTROL VALVE, DIPPER AND BUCKET SECTION VALVES
R E P A I R (CONT)
Safety Relief Valve
CAUTION
Caps or plugs must be installed in any ports not being tested to prevent
hydraulic oil leakage.
1.
Connect hand pump in port to be tested.
2.
Stroke hand pump until sufficient pressure is built up in circuit to open safety relief valve.
3.
Continue to stroke hand pump until all air has been pumped out of lines.
4.
Record highest pressure and compare with acceptable ranges shown below:
Swing Section Valve
A and B ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1700-1900 psi
(115.6-129.2 bar)
Boom Section Valve
Abort . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..925-1075 psi
(62.9-73.1 bar)
B port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..2400-2650 psi
(163.2-180.2 bar)
Dipper Section Valve
A and B ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..2400-2650 psi
(163.2-180.2 bar)
Bucket Section Valve
A and B ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..2400-2650 psi
(163.2 -180.2 bar)
20-77
|