TM 5-2420-224-34
FLUID REGULATING VALVE (P/N O 481 039 202) REPAIR (CONT)
WARNING
V e n t housing is under spring pressure. Wear safety goggles. Pressure must be
relieved slowly. Failure to do so could cause housing to fly off resulting in injury
t o personnel.
7.
OPEN VISE SLOWLY and REMOVE regulating valve HOUSING (3), vent housing (19), spring (20),
piston valve (21), ring (22), packing (23), filter screen (24), and filter (25). DISCARD PACKING.
REMOVE and DISCARD PACKING (26) from piston valve (21).
8.
9.
REMOVE cap (27), fitting (28), seal ring (29), tappet (30), PISTON (31), valve plate (32), and spring
(33) from regulating valve housing (3). DISCARD seal RING and valve PLATE.
10. REMOVE and DISCARD PACKING (34) from tappet (30).
17-31
|