TM 5-2420-224-34
STARTER REPAIR (CONT)
5.
Following directions provided with tester and using probe, test commutator bars (3) for abnormal
readings that will indicate a short, open, or poor connection. If any of these conditions are present,
replace armature (1).
NOTE
If brush holder has not been removed, make sure brush holder does not contact housing
while performing step 6.
6.
Using multimeter set to check continuity, check between field connector (4) and housing (5). Meter
reading should be infinity. If meter deflects toward zero, replace housing.
7.
Repeat step 6 for field connector (6) on opposite side of housing (5).