TM 5-2420-224-34
WATER PUMP REPAIR (CONT)
CAUTION
Make sure all gasket material
has been removed from both
mating  surfaces  to  prevent
d a m a g e to equipment.
INSTALL RETAINER (9), new gasket (11),
6.
and six screws (12).
INSTALL new seal (13) and new IMPELLER
7.
(14) on shaft (7).
USING feeler GAGE, CHECK CLEARANCE
8.
between impeller (14) and pump (4).
Clearance should be 0.012-0.043 in.
(0.30-1.1 mm).
CAUTION
Make sure all gasket material
has been removed from both
mating  surfaces  to  prevent
d a m a g e to equipment.
INSTALL rear COVER (15), new gasket (16),
9.
and four bolts (17).
13-76