TM 5-2420-224-34
OIL PUMP REPLACEMENT AND REPAIR (CONT)
USING suitable PRESS, INSTALL GEAR (5)
5.
on shaft (6).
USING suitable PRESS, INSTALL GEAR (5)
6.
and SHAFT (6) in housing (3).
USING feeler GAGE and STRAIGHTEDGE,
7.
CHECK CLEARANCE between gears (1 and
5) and housing (3). Clearance should be
0.0010-0.0035 in. (0.025-0.089 mm).
USING feeler GAGE, CHECK radial
8.
CLEARANCE between gears (1 and 5) and
sides of housing (3). Radial clearance should
be 0.001-0.005 in. (0.030-0.130 mm).