TM 5-2420-224-34
CYLINDER BLOCK REPAIR (CONT)
12. Measure diameter of tappet bores and refer to following table. If measurements are between repair
stages, tag crankcase for repair. If any measurement exceeds 1.134 in. (28.783 mm), replace
crankcase.
REPAIR
WARNING
Before machining crankcase, make sure crankcase is properly secured.
Failure to do so could result in injury to personnel.
If crankcase top is warped or has peaks and valleys, machine deck to next repair stage shown in
1.
Crankcase table in Inspection, above. If machining deck will bring height of crankcase below allowable
limits, replace crankcase.
If crankcase height is between repair stages, machine to next repair stage, unless that machining will
2.
bring height of crankcase below allowable limits.
13-52
|