CRANE EXTENSION BOOM REPLACEMENT (CONT)
With friction linings installed, measure height of friction lining above level surface of extension boom.
Thickness of friction lining above metal surface should not be less than 0.04-0.06 in. (0.1-0.2 cm). If
measurement is less, replace friction lining.
INSTALL two friction LININGS (1).
1.
2.
USING suitable HOIST, carefully SLIDE extension BOOM (2) into outer boom (3).
NOTE
Follow-on Maintenance:
Install crane external end extension cylinder (TM 5-2420-224-20).
Install crane hook assembly (TM 5-2420-224-20).
12-18