TM 5-2420-224-34
FORKLIFT LIFT CYLINDER REPLACEMENT, BLEEDING, AND
SEQUENCING (CONT)
1.
Remove bleeder valve (1) on top of slave
plunger (2).
I n s e r t key into bleed hole and engage
2.
adjusting nut (3).
NOTE
Adjusting nut is crimped slightly to
prevent free-turning, resulting in
stiff movement.
Turn adjusting nut (3) counterclockwise until it
3.
bottoms. Do not force adjusting nut after it
bottoms.
4.
Turn adjusting nut (3) clockwise two full turns
to provide initial adjustment. Remove key and
install bleeder valve (1).
11-55
|