TM 5-2420-224-34
FORKLIFT VALVE REPLACEMENT (CONT)
NOTE
Tag electrical connections prior to disconnecting to aid in connecting.
3.
DISCONNECT four electrical CONNECTIONS (4).
4.
REMOVE two capscrews (5), two washers (6), and VALVE (7).
1.
INSTALL VALVE (7), two washers (6), and two capscrews (5).
2.
CONNECT four electrical CONNECTIONS (4).
REMOVE CAPS or PLUGS. INSTALL eight new packings (3) and eight ELBOWS (2).
3.
4.
REMOVE CAPS or PLUGS. CONNECT eight hydraulic HOSE ASSEMBLIES (1).
NOTE
Follow-on Maintenance:
Install forklift (TM 5-2420-224-20).
11-39
|