TM 5-2420-224-34
TILT
AND
LATCH
CONTROL
VALVE
REPLACEMENT
AND
ADJUSTMENT
(CONT)
b . To increase pressure setting, turn
adjusting screw (3) to right. To
decrease pressure setting, turn
adjusting screw (3) to left.
c . Tighten lock nut (4) while holding
adjusting screw (3).
d. Repeat steps 2 and 3 to check
pressure
setting.
Readjust, if
necessary.
4.
Remove 0-5000 psi (0-352.1 bar) gage from
test port on inlet section of control valve (1).
NOTE
Step 5 is for the SEE. Step 6 is
for the HMMH.
5.
Set cover (6) in place and connect wire (7).
6.
Set cover (6) in place and connect two wires
(7).
7.
Install cover (6), seven washers (8), and
seven screws (9).
11-9
|