TM
5-2420-224-34
AIR SHIFT SOLENOID VALVE REPLACEMENT (CONT)
1.
INSTALL new straight tube ADAPTER (13) in air shift solenoid valve (2).
2.
INSTALL air shift solenoid VALVE (2), two washers (11), and two screws (10) on mounting bracket
(12).
3.
CONNECT two air LINES (4 and 5) to air shift solenoid valve (2) by INSTALLING two new preformed
packings (8), two new washers (9), and two fluid passage BOLTS (6 and 7).
4.
CONNECT air LINE (3) to air shift solenoid valve (2).
5.
CONNECT electrical CONNECTOR (1) to air shift solenoid valve (2).
NOTE
Follow-on Maintenance:
Lower cab (TM 5-2420-224-20).