Table 3-5. Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
ELECTRICAL SYSTEM (CONT)
Step 38. Check for +24 VDC between wire 7 and wire 14 (48) and ground at motor
relay (43).
If +24 VDC is not present, go to step 42.
If +24 VDC is present, go to step 39.
Step 39. Check for +24 VDC between wire 7 and wire 14 (48) and ground at
connector AA (46) and connector AB (24).
If +24 VDC is not present, repair wiring 7 and wiring 14
between motor relay and connector AA and connector AB.
If +24 VDC is present, go to step 40.
Step 40. Check for +24 VDC between wire 7 and wire 14 (48) and ground at cab
floor separation point (25).
If +24 VDC is not present, repair wiring 7 and wiring 14
between connector AA and connector AB and cab floor
separation point.
If +24 VDC is present, go to step 41.
3-231