Table 3-5. Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
ELECTRICAL SYSTEM (CONT)
Step 21. Check for +24 VDC between wire 712 (8) and ground at fast group relay
(32).
If +24 VDC is present, repair wiring 712 between fast group
relay and control switch.
If +24 VDC is not present, go to step 22.
Step 22. Check for +24 VDC between wire 71 (33) and ground at fast group relay
(32).
If +24 VDC is present, go to step 27.
If +24 VDC is not present, go to step 23.
Step 23. Check for +24 VDC between wire 71 (33) and ground at connector AG (34).
If +24 VDC is present, repair wiring 71 between fast group
relay and connector AG.
If +24 VDC is not present, go to step 24.
Step 24. Check for +24 VDC between wire 71 (33) and ground at pin 4 of forklift
wiring harness connector (35).
If +24 VDC is present, repair wiring 71 between connector AG
and forklift wiring harness connector.
If +24 VDC is not present, go to step 25.
3-225