TM
5-2420-224-20-1
Table 3-5. Troubleshooting (Cont)
Malfunction
Test or InspectIin
Corrective Action
ELECTRICAL SYSTEM (CONT)
Step 19. Check for +24 VDC between wire 10 (23) and ground at pin 1 of solenoid
connector (30).
If +24 VDC is not present, repair wiring 10 between cab floor
separation point and solenoid connector.
If +24 VDC is present, go to step 20.
Step 20. Check wire 02 (31) at solenoid connector (30) for continuity to ground.
If open to ground, repair wiring 02 between solenoid and
ground at NATO slave receptacle.
If short to ground, replace hydraulic suspension lockout pump
(page 4-51 1).
3-224
|