TM 5-2420-224-20-1
Table 3-5. Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
ELECTRICAL SYSTEM (CONT)
72. Hydraulic Suspension LOCKOUT WILL NOT ENGAGE (HMMH).
NOTE
Electrical quick disconnect for forklift must be connected to vehicle.
Step 1. Remove four screws (1), four washers (2), four spring tension washers (3),
and passenger seat (4).
NOTE
For steps 2 thru 49, engine must be running and clutch depressed. Failure to do
..
so will cause erroneous results.
Refer to wiring diagram (page 3-235) for all wiring repair steps.
Step 2. Pull and release suspension lockout control switch (5).
If indicator light lights when control switch is pulled but goes
out when control switch is released, go to step 8.
If indicator light is not lit but pump motor is running, go to
step 14.
If indicator light is lit, pump motor is running, but lockout is
not engaged, go to step 16.
if indicator light is lit but pump motor is not running, go to
step 32.
If indicator light is not lit and pump motor is not running, go to
step 3.
|