TM 5-2420-224-20-1
Table 3-5. Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
ELECTRICAL SYSTEM (CONT)
Step 5.
Disconnect master light switch connector (7) and check for continuity
between terminal A and terminal B of master light switch (8).
If there is continuity, repair wiring 49 between master light
switch and connector K.
If there is no continuity, replace master light switch
(page 4-137).
Step 6.
Check for +24 VDC between wire 494 (9) and ground at voltmeter
gage (10).
If +24 VDC is present, replace voltmeter gage (page 4-135).
If +24 VDC is not present, repair wiring 494 between indicator
(gage) and voltmeter gage.
VOLTM ETER
GAGE
Change 1
|