TM 5-2420-224-20-1
Table 3-5. Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
ELECTRICAL SYSTEM (CONT)
Step 5. Check for +24 VDC between wire 41HL (9) and ground at auxiliary tight
control switch (8).
If +24 VDC is present, replace auxiliary light control switch
(page 4-146).
If +24 VDC is not present, go to step 6.
Step 6. Disconnect connector G (10) and check for +24 VDC between wire 41HL (9)
and ground.
If +24 VDC is present, repair wiring 41HL between connector G
and auxiliary light control switch.
If +24 VDC is not present, reconnect connector G and go to
step 7.
Step 7. Check for +24 VDC between wire 41HL (9) and ground at fuse box 2 (11).
If +24 VDC is not present, replace fuse.
If +24 VDC is present, repair wiring 41HL between fuse box 2
and connector G.
|