TM
5-2420-224-20-1
Table 3-5. Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
ELECTRICAL SYSTEM (CONT)
Step 6. Check for +24 VDC between wire 41HR1 (10) and ground at auxiliary light
control switch (11).
If
+24 VDC is present, repair wiring 41HR1.
If
+24 VDC is not present, go to step 7.
Step 7. Check for +24 VDC between wire 41HR (12) and ground at auxiliary light
control switch (11).
If +24 VDC is present, replace auxiliary Iight control switch
(page 4-146).
If +24 VDC is not present, go to step 8.