TM 5-2420-222-34 14-6. HYDRAULIC PUMP STROKE CONTROL VALVE REPAIR. This Task Covers: a. Disassembly c. Assembly b. Cleaning and Inspection Initial Setup: Equipment Conditions: Materials/Parts: Hydraulic pump stroke control valve removed Hydraulic fluid (Item 15, Appendix B) from hydraulic pump (see paragraph 14-3). Rags (Item 28, Appendix B) Dry cleaning solvent (Item 31, Appendix B) Two repair kits Tools/Test Equipment: General mechanic's tool kit Field automotive shop set References: Two drivers TM 5-2420-222-20 General Safety Instructions: Dry cleaning solvent is flammable and must not be used near open flame.  Use only in a well-ventilated area. a. DISASSEMBLY 1. Remove  eight  preformed  packings  (10),  preformed  packing (9), and preformed packing (11) from control valve body (3). Discard preformed packings. 2. Remove preformed packing (8).  Discard preformed packing. 3. Remove two plugs (2).  Remove two preformed packings (1) from plugs.  Discard preformed packings. 4. Remove drain plug (5).  Remove preformed packing (4) from drain plug.  Discard preformed packing. 5. Remove plug (7).  Remove preformed packing (6) from plug. Discard preformed packing. TA701565 14-32

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business