TM 5-2420-222-34
7-1.
ENGINE AC GENERATOR REPAIR (Cont).
5.
Remove automotive generator and starter test stand jumper wire (54) from output terminal (53) and regulator
terminal (55) on AC generator (50).
6.
Connect automotive generator and starter test stand voltmeter to output terminal (53) and ground terminal (52).
7.
Open automotive generator and starter test stand variable resistor and check voltage regulator operation. Voltage
regulator (51) should maintain AC generator output voltage from 13-15 v.
8.
Disconnect automotive generator and starter test stand voltmeter from output terminal (53) and ground terminal
(52).
9.
Remove AC generator (50) from automotive generator and starter test stand.
FOLLOW-ON TASKS:
Install AC generator pulley (see TM 5-2420-222-20).
Install AC generator (see TM 5-2420-222-20).
7-13
|