TM 5-2420-222-34 7-1. ENGINE AC GENERATOR REPAIR (Con’t). 5. Remove  automotive  generator  and  starter  test  stand  jumper  wire  (54)  from  output  terminal  (53)  and  regulator terminal (55) on AC generator (50). 6. Connect automotive generator and starter test stand voltmeter to output terminal (53) and ground terminal (52). 7. Open automotive generator and starter test stand variable resistor and check voltage regulator operation. Voltage regulator (51) should maintain AC generator output voltage from 13-15 v. 8. Disconnect automotive generator and starter test stand voltmeter from  output  terminal  (53)  and  ground  terminal (52). 9. Remove AC generator (50) from automotive generator and starter test stand. FOLLOW-ON TASKS: Install AC generator pulley (see TM 5-2420-222-20). Install AC generator (see TM 5-2420-222-20). 7-13