TM 5-2420-222-34
5-5.
SPEED CONTROL SHAFT REPLACEMENT (Cont).
b.
CLEANING AND INSPECTION
WARNING
Dry cleaning solvent, P-D-680, Is toxic and flammable. Always wear protective
goggles and gloves, and use only In a well-ventilated area. Avoid contact with
skin, eyes, and clothes, and DO NOT breathe vapors. DO NOT use near open flame
or excessive heat. The solvent's flash point Is 100°F-138°F (38°C-59°C). If you
become dizzy while using cleaning solvent, immediately get fresh air and medical
help. If solvent contacts eyes, Immediately wash your eyes and get medical aid.
1.
Clean speed control shaft with dry cleaning solvent. Wipe dry with clean, dry rags.
2.
Inspect speed control shaft for cracks, breaks, abnormal bends, and excessive wear at cowl support contact
points. Replace if defective.
c.
INSTALLATION
1.
Apply grease to cowl support contact points on speed control shaft (2).
2.
Slide speed control shaft (2) in cowl support (3).
3.
Install speed control rod (1), washer (5), and new cotter pin (4) in speed control shaft (2).
FOLLOW-ON TASKS:
Install cowl support (see paragraph 13-5).
Install speed control arms (see TM 5-2420-222-20).