JAW DIRECT LINEAR VALVE (SERIAL NUMBERS 319995 THRU 342573 ONLY) - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
DISASSEMBLY - CONTINUED
13.
Valve (1) and
Two nuts
Using 13/16-inch and 7/8-inch open-end
two bulkhead
(4 and 5)
wrenches, loosen.
elbows (2 and 3)
14.
Valve (1)
Two bulkhead
a.
Note relative position for proper
elbows (2 and 3)
placement during assembly.
with attached parts
b.
Using 13/16-inch open-end wrench,
unscrew and take out.
15.
Two bulkhead
Two packings
a.
Using pocket knife, take off.
elbows (2 and 3)
(6 and 7)
b.
Get rid of.
16.
Valve(1)
Plug (8)
a.
Using 1 1/2-inch open-end wrench,
with assembled
unscrew and take off.
packing (9)
b.
Take valve (1) out of machinists vise
with vise jaw caps.
17.
Plug (8)
Packing (9)
a.
Using pocket knife, take off.
b.
Get rid of.
CLEANING
NOTE
For more information on how to clean parts, go to General Maintenance Instructions
(page 2-137).
WARNING
Dry-cleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and
gloves and use only in a well ventilated area. Avoid contact with skin, eyes, and clothes
and dont breathe vapors. Do not use near open flame or excessive heat. The
flashpoint is 100°F to 138°F (38° to 59°C). If you become dizzy while using cleaning
solvent, get fresh air immediately and get medical aid. If contact with eyes is made,
wash your eyes with water and get medical aid immediately.
18.
Valve (1)
a.
Using clean rags dampened with dry-
cleaning solvent, wipe clean.
b.
Using clean, dry rags, wipe dry.
19.
All other metal
a.
Clean in dry-cleaning solvent.
parts
b.
Using clean, dry rags, wipe dry.
2-1254
|