TM 5-2420-222-20-3
HYDRAULIC PUMP-TO-SPEED GEAR ASSEMBLY (REVERSER) SEAL DRAIN LINE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING - CONTINUED
WARNING
Drycleaning solvent P-D-680 is toxic and flammable Wear protective goggles and gloves and use
only in a well ventilated area Avoid contact with skin, eyes, and clothes and dont breathe vapors
Do not use near open flame or excessive heat The flashpoint is 100°F to 138°F (38° to 59°C) If you
become dizzy while using cleaning solvent, get fresh air immediately and get medical aid If
contact with eyes is made, wash your eyes with water and get medical aid immediately.
11
All metal parts
a
Clean in drycleaning solvent.
b
Using clean, dry rags, wipe dry.
INSPECTION/REPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance
Instructions (page 2-137). Replace defective parts as needed.
12.
Oil line (1)
Look for cracks and breaks.
13.
All metal parts
Look for cracks, breaks, and abnormal
bends.
14.
All threaded parts
Look for damaged threads.
INSTALLATION
15
Speed gear assembly
Straight
a
Unplug cover (2).
top cover (2)
adapter (3)
b
Screw in and tighten using 7/16-inch
open-end wrench.
16
Straight
Oil line (1)
a
Take off tag.
adapter (3)
b
Screw on and tighten using two 7/16-
inch open-end wrenches.
17
Oil line (1)
Seven new electrical
a
Place in position at locations noted
tie down bands (4)
during removal.
b
Using slip-joint pliers, tighten.
2-1372
|