TM 5-2420-222-20-3
HYDRAULIC PUMP-TO-HYDRAULIC OIL COOLER OIL LINE (SERIAL NUMBERS 235786 THRU 235999 ONLY) -
CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING - CONTINUED
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and
gloves and use only in a well ventilated area. Avoid contact with skin, eyes, and
clothes and dont breathe vapors. Do not use near open flame or excessive heat.
The flashpoint is 100°F to 138°F (38° to 59°C). If you become dizzy while using
cleaning solvent, get fresh air immediately and get medical aid. If contact with
eyes is made, wash your eyes with water and get medical aid immediately.
9.
All metal parts
a.
Clean in drycleaning solvent.
b.
Using clean, dry rags, wipe dry.
INSPECTION/REPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-
137).
Replace defective parts as needed.
10.
All rubber parts
Look for cracks, breaks, and tears.
11.
All metal parts
Look for cracks, breaks, and abnormal bends.
12.
All threaded parts
Look for damaged threads.
INSTALLATION
13. Special adapter (1)
Hose (2)
a.
Uncap special adapter (1).
b.
Put on.
14. Hose (2)
Two clamps (3)
Place in position.
15. Oil cooler (4)
Hose (5)
a.
Uncap oil cooler (4).
b.
Put on.
16. Hose (5)
Two clamps (6)
Place in position.
17. Two hoses
Oil line (7)
a.
Take off tag.
(2 and 5)
b.
Place in position.
18. Hose (2)
Two clamps (3)
Using 3/16-inch flat-tip screwdriver, tighten.
2-1344
|