TM 5-2420-222-20-2
HYDRAULIC OIL COOLER - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REMOVAL - CONTINUED
WARNING
Water soluble cleaning compound solvent is flammable and fumes are toxic. Flashpoint is 220°F (104°C).
Boiling point is 212°F (100°C). Do not store in temperatures above 150°F (65°C) or below 35°F (2°C). Do
not use near open flame or excessive heat. Do not wear jewelry, wear rubber gloves and goggles, and
use only in well ventilated area. Avoid contact with skin, eyes, and clothes, and don't breathe vapors.
Avoid contact with acids, aluminum, or zinc; chemical reaction may result. If you become dizzy while
using cleaning compound solvent, get fresh air immediately and get medical aid. If contact with eyes is
made, wash your eyes with water and get medical aid immediately.
CAUTION
Do not remove baffles unless inspection shows need for replacement. Removal may damage part.
10.
Oil cooler (1)
Two baffles
a.
Using cleaning compound solvent,
(2 and 3)
dissolve adhesive and take off.
b.
Using clean rag soaked in cleaning
compound solvent, remove all adhesive
from cooler (1).
c.
Using clean rag dampened with clean
water, wipe cooler (1) clean.
d.
Using clean, dry rag, wipe cooler (1)
dry.
CLEANING
NOTE
For more information on how to clean parts, go to General Maintenance Instructions (page 2-137).
11.
Oil cooler
Clean (TM 750-254).
12.
Rubber washer (4)
a.
Using clean, dry rag dampened with
solution of detergent and water,
wipe clean.
b.
Rinse with clean water.
c.
Using clean, dry rag, wipe dry.
2-844
|