TM 5-2420-222-20-2
SPEED GEAR ASSEMBLY (REVERSER) CONTROL LEVER LINKAGE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING
NOTE
For more information on how to clean parts, go to General Maintenance Instructions (page 2-137).
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and gloves and use only in
a well ventilated area. Avoid contact with skin, eyes, and clothes and dont breathe vapors. Do not use
near open flame or excessive heat. The flashpoint is 100°F to 1380F (380 to 590C). If you become dizzy
while using cleaning solvent, get fresh air immediately and get medical aid. If contact with eyes is made,
wash your eyes with water and get medical aid immediately.
22.
All parts
a.
Clean in drycleaning solvent.
b.
Using clean dry rags, wipe dry.
INSPECTION/REPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-137).
Replace defective parts which cannot be repaired.
23.
All parts
Look for cracks, breaks, and abnormal
bends.
24.
All threaded parts
Look for damaged threads.
REPAIR
25.
All threaded parts
If threads are damaged, using screw
except attaching
threading set, restore threads.
hardware
ASSEMBLY
26.
Control lever
Yoke (2) and nut (3)
a.
Place rod (1) in machinist's vise.
rod (1)
b.
Screw on until number of threads
showing on rod (1) and relative
position of yoke (2) are same as noted
in disassembly.
2-820
|