TM 5-2420-222-20-2
TRANSMISSION - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
DRAINING - CONTINUED
WARNING
Be careful when draining hot fluids. Wear gloves to protect your hands from hot parts and fluids
or severe burns could result.
4.
Transmission
Drainplug (2) with
a.
Place 10-gallon container underneath.
case (1)
assembled
b.
Using 1 1/4-inch, 3/4-inch drive
packing (3)
socket and ratchet handle, unscrew
and take out.
c.
Allow hydraulic fluid to drain into
into 10-gallon container.
5.
Drainplug (4) with
a.
Place 10-gallon container underneath.
assembled
b.
Using 1 1/4-inch, 3/4-inch drive
packing (3)
socket and ratchet handle, unscrew
and take out.
c.
Allow hydraulic fluid to drain into
into 10-gallon container.
d.
Get rid of drained fluid (page 2-137).
6.
Two drainplugs
Two packings
a.
Take off.
(2 and 4)
(3 and 5)
b.
Get rid of.
7.
Two new packings
Place in position.
(3 and 5)
8.
Transmission
Two drainplugs
Screw in and tighten using 1 1/4-inch,
case (1)
(2 and 4) with
3/4-inch drive socket and ratchet handle.
packings (3 and 5)
FILLING
9.
Center platform (6)
Filler lock (7)
Move aside.
10.
Filler tube (8)
Dipstick (9)
a.
Loosen.
b.
Pull out.
c.
Using clean, dry rag, wipe off fluid.
11.
Transmission
Filler tube (8)
Add proper amount and grade of hydraulic
cover (10)
fluid (LO 5-2420-222-12).
2-812
|