TM 5-2420-222-20-2 AC GENERATOR PULLEY - CONTINUED ACTION LOCATION ITEM REMARKS 12. Rotor shaft (1) Pulley (4) a. Aline with keyway. and woodruff key (3) b. Put on. CAUTION Make sure machinist’s vise grips both flanges of pulley to prevent bending it. 13. Pulley (4) and New lockwasher (5) a. Secure pulley (4) in machinist’s vise rotor shaft (1) and nut (2) with vise jaw caps and support ac generator (6). b. Using 15/16-inch, 1/2-inch drive socket, 5-inch extension, and ratchet handle, screw on until snug. c. Using 15/16-inch, 1/2-inch drive socket, 5-inch extension, and 0 to 150 foot-pound capacity torque wrench, tighten to 40 to 50 foot pounds (55 to 67 N.m) torque. d. Remove pulley (4) from machinist’s vise with jaw caps. NOTE FOLLOW-ON MAINTENANCE: Install ac generator (page 2-436). TASK ENDS HERE TA242930 2-451