WATER PUMP - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING - CONTINUED
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and gloves and use only
in a well ventilated area. Avoid contact with skin, eyes, and clothes and don't breathe vapors. Do not
use near open flame or excessive heat. The flashpoint is 1000F to 1380F (380 to 590C). If you become
dizzy while using cleaning solvent, get fresh air Immediately and get medical aid. If contact with eyes is
made, wash your eyes with water and get medical aid immediately.
17.
Water pump (1)
a. Using clean rags dampened with dry-
cleaning solvent, wipe clean.
b. Using clean, dry rags, wipe dry.
18.
All other metal
a. Clean in drycleaning solvent.
parts
b. Using clean, dry rags, wipe dry.
INSPECTION/REPLACEMENT
NOTE
For more Information on how to inspect parts, go to General Maintenance Instructions (page 2-137).
Replace defective parts as needed.
19.
Water pump (1)
a. Look for signs of leaking at shaft and
drain hole.
Leakage at drain hole Indicates
defective Internal seal.
b. Turn shaft by hand.
Shaft should turn quietly with
slight drag.
c.  Look for cracks, breaks, and damaged
gasket sealing surface.
20.
All other metal
Look for cracks, breaks, and abnormal
parts
bends.
21.
All threaded
Look for damaged threads.
parts
2-412