HAND THROTTLE CABLE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REMOVAL - CONTINUED
14.
Bracket (1) and
Screw (3) and
a. Using 9/16-inch, 3/8-inch drive socket
cowl support (2)
lockwasher (4)
and ratchet handle, unscrew and take
out.
b. Get rid of lockwasher (4).
15.
Cowl support (2)
Bracket (1)
Take off.
DISASSEMBLY
16.
Cable (5)
Swivel (6)
a. Position cable (5) in machinist's vise
with vise jaw caps.
b. Note number of exposed threads on
cable (5) for proper placement during
installation.
c.  Using 1/2-inch open-end wrench,
unscrew and take off.
d. Take cable (5) out of machinist's vise
with vise jaw caps.
CLEANING
NOTE
For more information on how to clean parts, go to General Maintenance Instructions (page 2-137).
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and gloves and use only in
a well ventilated area. Avoid contact with skin, eyes, and clothes and don't breathe vapors. Do not use
near open flame or excessive heat. The flashpoint is 1000F to 1380F (380 to 590C). If you become dizzy
while using cleaning solvent, get fresh air immediately and get medical aid. If contact with eyes is made,
wash your eyes with water and get medical aid immediately.
17.
Cable (5)
a. Using clean rags dampened in dry-
cleaning solvent, wipe clean.
b. Using clean, dry rags, wipe dry.
18.
All other parts
a. Clean in drycleaning solvent.
b. Using clean, dry rags, wipe dry.