TM 5-2420-222-20-1
ENGINE STARTING AID FLUID INJECTION TUBE AND FITTINGS - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING - CONTINUED
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and gloves and use only in a well
ventilated area. Avoid contact with skin, eyes, and clothes and don't breathe vapors. Do not use near open
flame or excessive heat. The flashpoint is 1000F to 1380F (380 to 590C). If you become dizzy while using
cleaning solvent, get fresh air immediately and get medical aid. If contact with eyes is made, wash your
eyes with water and get medical aid immediately.
8.
All other parts
a. Clean in drycleaning solvent.
b. Using clean, dry rags, wipe dry.
INSPECTION/REPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-137).
Replace defective parts as needed.
9.
Tube (1)
Look for cracks, cuts, and breaks.
10.
All other parts
Look for cracks, bends, breaks, and other
other physical damage.
11.
All threaded parts
Look for damaged threads.
INSTALLATION
WARNING
Ether burns easily. If engine starting aid is not properly installed, do not release ether in confined areas or
near open flame. Engine primer fluid cylinder is pressurized to expel ether when fluid injection solenoid is
activated. Do not heat engine primer fluid cylinder or place it in fire.
12.
Spray nozzle
Spray nozzle (3)
Screw in and tighten using 1/4-inch box
holder (2)
wrench.
13.
Air Inlet (4)
Spray nozzle
Screw in and tighten using 3/4-inch box
holder (2)
wrench.