TM 5-2420-222-20-1
FUEL FILTER-TO-FUEL METERING PUMP FUEL LINE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING CONTINUED
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and gloves and use only
in a well ventilated area. Avoid contact with skin, eyes, and clothes and don't breathe vapors. Do not
use near open flame or excessive heat. The flashpoint is 1000F to 1380F (380 to 590C). If you become
dizzy while using cleaning solvent, get fresh air immediately and get medical aid. If contact with eyes is
made, wash your eyes with water and get medical aid immediately.
5.
All parts
a. Clean in drycleaning solvent.
b. Using clean, dry rags, wipe dry.
INSPECTION/REPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-137).
Replace defective parts as needed.
6.
All parts
a. look for cracks, breaks, and abnormal bends.
b. Look for damaged threads.
INSTALLATION
WARNING
No open flames, welding, grinding, smoking, or use of heat producing devices permitted near fuel tank
and fuel lines during maintenance unless the fuel tank has been cleaned and purged of all flammable
liquids and vapors. Fuel burns easily and fumes are explosive. Keep battery disconnected. Failure to
observe these precautions could cause serious Injury.
7. Sleeve (1)
Elbow (2)
a. Unplug sleeve (1).
b. Screw in and tighten to position noted during
removal using 0 to 1.322-inch adjustable
wrench.
8. Elbow (2)
Line (3)
Screw on and tighten using 5/8-inch open-end
wrench.
2-294
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |