![]() TM 5-2420-222-20-1 
FUEL FILTER-TO-FUEL METERING PUMP FUEL LINE - CONTINUED 
ACTION 
LOCATION 
ITEM 
REMARKS 
CLEANING CONTINUED 
WARNING 
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and gloves and use only 
in a well ventilated area. Avoid contact with skin, eyes, and clothes and don't breathe vapors. Do not 
use near open flame or excessive heat. The flashpoint is 1000F to 1380F (380 to 590C). If you become 
dizzy while using cleaning solvent, get fresh air immediately and get medical aid. If contact with eyes is 
made, wash your eyes with water and get medical aid immediately. 
5. 
All parts 
a. Clean in drycleaning solvent. 
b. Using clean, dry rags, wipe dry. 
INSPECTION/REPLACEMENT 
NOTE 
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-137). 
Replace defective parts as needed. 
6. 
All parts 
a. look for cracks, breaks, and abnormal bends. 
b. Look for damaged threads. 
INSTALLATION 
WARNING 
No open flames, welding, grinding, smoking, or use of heat producing devices permitted near fuel tank 
and fuel lines during maintenance unless the fuel tank has been cleaned and purged of all flammable 
liquids and vapors. Fuel burns easily and fumes are explosive. Keep battery disconnected. Failure to 
observe these precautions could cause serious Injury. 
7. Sleeve (1) 
Elbow (2) 
a. Unplug sleeve (1). 
b. Screw in and tighten to position noted during 
removal using 0 to 1.322-inch adjustable 
wrench. 
8. Elbow (2) 
Line (3) 
Screw on and tighten using 5/8-inch open-end 
wrench. 
2-294 
 | 
| 
 