Click here to make tpub.com your Home Page

Page Title: CLEANING
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 5-2420-222-20-1
FUEL FILTER ASSEMBLY - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING
NOTE
For more information on how to clean parts, go to General Maintenance Instructions (page 2-137).
9. Two bleed plugs (1)
a. Clean in solution of detergent and
water.
b. Using clean, dry rags, wipe dry.
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and gloves and use only
in a well ventilated area. Avoid contact with skin, eyes, and clothes and don't breathe vapors. Do not
use near open flame or excessive heat. The flashpoint is 1000F to 1380F (380 to 590C). If you become
dizzy while using cleaning solvent, get fresh air Immediately and get medical aid. If contact with eyes is
made, wash your eyes with water and get medical aid immediately.
10. All metal parts
a. Clean in drycleaning solvent.
b. Using clean, dry rags, wipe dry.
INSPECTION/REPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-137).
Replace defective parts which cannot be repaired.
11.
All parts
Look for cracks and breaks.
12.
All threaded parts
Look for damaged threads.
REPAIR
13.
Filter head (2)
If threads are damaged, using pipe
thread set, restore threads.
2-280

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business