![]() TM 5-2420-222-20-1 
FUEL PUMP - CONTINUED 
ACTION 
LOCATION 
ITEM 
REMARKS 
DISASSEMBLY - CONTINUED 
WARNING 
No open flames, welding, grinding, smoking, or use of heat producing devices permitted 
near fuel tank and fuel lines during maintenance unless the fuel tank has been cleaned 
and purged of all flammable liquids and vapors.  Fuel burns easily and fumes are 
explosive. Keep battery disconnected. Failure to observe these precautions could 
cause serious injury. 
6. Fuel pump (1) 
Lever (2) with 
a. Press fuel pump rocker arm lever (4). 
assembled 
b. Take out. 
packing (3) 
c.  Release fuel pump rocker arm lever. 
7. Lever (2) 
Packing (3) 
a. Using pocket knife, take off. 
b. Get rid of. 
CLEANING 
NOTE 
For more information on how to clean parts, go to General Maintenance Instructions 
(page 2-137). 
WARNING 
Drycleaning solvent PD680 is toxic and flammable.  Wear protective goggles and 
gloves and use only in a well ventilated area. Avoid contact with skin, eyes, and clothes 
and don't breathe vapors.  Do not use near open flame or excessive heat.  The 
flashpoint is 1000F to 1380F (380 to 590C). If you become dizzy while using cleaning 
solvent, get fresh air immediately and get medical aid. If contact with eyes is made, 
wash your eyes with water and get medical aid immediately. 
8. 
Fuel pump (1) 
a. Using clean rags dampened in dry- 
cleaning solvent, wipe clean. 
b. Using clean, dry rags, wipe dry. 
9. 
All other 
a. Clean in drycleaning solvent. 
metal parts 
b. Using clean, dry rags, wipe dry. 
2-228 
 | 
| 
 
 Privacy Statement - Press Release - Copyright Information. - Contact Us  |