TM 5-2420-222-20-1
CLUTCH PEDAL - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING - CONTINUED-
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and gloves and use only in
a well ventilated area. Avoid contact with skin, eyes, and clothes and don't breathe vapors. Do not use
near open flame or excessive heat. The flashpoint is 100F to 1380F (380 to 590C). If you become dizzy
while using cleaning solvent, get fresh air immediately and get medical aid. If contact with eyes is made,
wash your eyes with water and get medical aid immediately.
15.
All metal parts
a. Clean in drycleaning solvent.
b. Using clean, dry rags, wipe dry.
INSPECTIONIREPLACEMENT
NOTE
For more information on how to Inspect parts, go to General Maintenance Instructions (page 2-137).
Replace defective parts as needed.
16.
Pad (1)
Look for tears and crumbling.
17.
All metal parts
Look for cracks, bends, and breaks.
18.
All threaded parts
Look for damaged threads.
ASSEMBLY
19.
Pedal (2)
Stop (3)
Place in position.
20.
Pedal (2) and
Two washers (4)
Place in position.
stop (3)
21.
Pedal (2),
Pin (5)
a. Aline holes in pedal (2), stop (3) and
stop (3), and
two washers (4).
two washers (4)
b. Using 1-pound head ball-peen hammer,
tap in.
22.
Pedal (2)
Pad (1)
Place In position.
23.
Bushing (6)
If removed, using 1.0625inch remover
and installer and arbor press, press In.
2-198
|