|
|
TM 5-2420-222-20-1
LUBRICATING COOLER (ENGINE OIL COOLER) - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING
NOTE
For more information on how to clean parts, go to General Maintenance Instructions (page 2-137).
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and gloves and use
only in a well ventilated area. Avoid contact with skin, eyes, and clothes and don't breathe vapors. Do
not use near open flame or excessive heat. The flashpoint Is 1000F to 1380F (380 to 590C). If you
become dizzy while using cleaning solvent, get fresh air immediately and get medical aid. If contact
with eyes is made, wash your eyes with water and get medical aid immediately.
9.
All parts
a. Clean in drycleaning solvent.
b. Using clean, dry rags, wipe dry.
INSPECTION/REPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-137).
Replace defective parts that cannot be repaired.
10.
All metal parts
Look for cracks, breaks, and abnormal
bends.
11. Cooler (1)
Valve (2)
Using hand pump, flow control valve,
handle, and pressure gage, measure
opening pressure.
Valve should open at 12 to 15
psi
(83 to 103 kPa).
12
All threaded parts
Look for damaged threads.
REPAIR
13.
Nipple (3) and
If threads are damaged, using pipe thread
cooler (1)
set, restore threads.
2-158
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |