![]() TM 5-2420-222-20-1 
VALVES - CONTINUED 
ACTION 
LOCATION 
ITEM 
REMARKS 
ADJUSTMENT - CONTINUED 
1. 
Cover (1) and 
Pin (3) 
Using 314-inch open-end wrench, unscrew 
housing (2) 
and take out. 
2. 
Housing (2) 
Cover (1) 
Take off. 
3. 
Crankshaft 
Hydraulic pump 
Using 1 to 2-inch adjustable pipe wrench, 
pulley (4) 
drive shaft (5) 
turn until number one cylinder is at top dead 
center. 
Number one cylinder is at top dead 
center when both of Its valves are fully 
closed and hole In flywheel is alined with 
timing hole in housing. 
NOTE 
If pin cannot be Inserted all the way into flywheel, repeat step 3. 
4. 
Housing (2) and 
Pin (3) 
Slide through timing hole in housing (2) 
flywheel (6) 
until seated in hole in flywheel (6). 
5. 
Number one and 
Two valves (9 and 
While measuring clearance between valves 
number three 
10) and two 
(9 and 10) and rocker arms (7 and 8) with 
exhaust valve 
adjusting screws 
thickness gage, using 1/2-inch open-end 
rocker arms 
(11 and 12) 
wrench, turn screws (11 and 12) in or out 
(7 and 8) 
as needed to get correct clearance. 
Correct clearance is 0.018 inch (0.46 mm). 
6. 
Number one and 
Two valves (15 and 
While measuring clearance between valves 
number two 
16) and two 
(15 and 16) and rocker arms (13 and 14) 
intake valve 
adjusting screws 
with thickness gage, using 112-inch open- 
rocker arms 
(17 and 18) 
end wrench, turn screws (17 and 18) in or 
(13 and 14) 
out as needed to get correct clearance. 
Correct clearance Is 0.014 Inch (0.36 mm). 
7. 
Housing (2) and 
Pin (3) 
Take out. 
flywheel (6) 
8. 
Crankshaft 
Hydraulic pump 
Using 1 to 2-inch adjustable pipe wrench, 
pulley (4) 
drive shaft (5) 
turn until number four cylinder is at top dead 
center. 
2-150 
 | 
| 
 