![]() TM 5-2420-222-20-1 
ENGINE - CONTINUED 
ACTION 
LOCATION 
ITEM 
REMARKS 
DRAINING - CONTINUED 
WARNING 
Be careful when draining hot fluids. Wear gloves to protect your hands from hot parts and fluids or severe 
burns could result. 
2 
Oil pan (1) 
Plug (2) and 
a. Place 10-gallon container underneath. 
washer (3) 
b. Using 1 118-inch open-end wrench, 
unscrew and take out. 
c.  Get rid of washer (3). 
d. Let oil drain completely. 
e. Get rid of drained oil (page 2-137). 
CLEANING 
NOTE 
For more information on how to clean parts, go to General Maintenance Instructions (page 2-137). 
WARNING 
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and gloves and use only in 
a well ventilated area. Avoid contact with skin, eyes, and clothes and don't breathe vapors. Do not use 
near open flame or excessive heat. The flashpoint is 1000F to 1380F (380 to 590C). If you become dizzy 
while using cleaning solvent, get fresh air immediately and get medical aid. If contact with eyes is made, 
wash your eyes with water and get medical aid immediately. 
3. 
Plug (2) 
a. Clean in drycleaning solvent. 
b. Using clean, dry rags, wipe dry. 
INSPECTION/REPLACEMENT 
NOTE 
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-137). 
Replace defective parts as needed. 
4. 
Plug (2) 
a. Look for cracks and breaks. 
b. Look for damaged threads. 