ENGINE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
DRAINING - CONTINUED
WARNING
Be careful when draining hot fluids. Wear gloves to protect your hands from hot parts and fluids or severe
burns could result.
2
Oil pan (1)
Plug (2) and
a. Place 10-gallon container underneath.
washer (3)
b. Using 1 118-inch open-end wrench,
unscrew and take out.
c.  Get rid of washer (3).
d. Let oil drain completely.
e. Get rid of drained oil (page 2-137).
CLEANING
NOTE
For more information on how to clean parts, go to General Maintenance Instructions (page 2-137).
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and gloves and use only in
a well ventilated area. Avoid contact with skin, eyes, and clothes and don't breathe vapors. Do not use
near open flame or excessive heat. The flashpoint is 1000F to 1380F (380 to 590C). If you become dizzy
while using cleaning solvent, get fresh air immediately and get medical aid. If contact with eyes is made,
wash your eyes with water and get medical aid immediately.
3.
Plug (2)
a. Clean in drycleaning solvent.
b. Using clean, dry rags, wipe dry.
INSPECTION/REPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-137).
Replace defective parts as needed.
4.
Plug (2)
a. Look for cracks and breaks.
b. Look for damaged threads.