ORGANIZATIONAL TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 1. Check to see that reverse warning alarm (7) is tightly mounted.
a. If alarm (7) is tightly mounted, go to step 2.
b. If alarm (7) is loose, tighten four screws (8) and four nuts (9) using 1/2-inch, 3/8-inch drive
socket, ratchet handle, and 1/2-inch open-end wrench.
Step 2. Check reverse warning alarm terminals (10 and 11) for loose, frayed, corroded, or broken connections.
a. If connections at terminals (10 and 11) are not loose, frayed, corroded, or broken, go to step 3.
b. If connection at terminal (10 or 11) is loose, tighten nut (12 or 13) using 318-inch box wrench.
2-103