ORGANIZATIONAL TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
a.
If multimeter reads 0 ohm, go to step 3.
b.
If multimeter reads more than 0 ohm, replace bulb and install indicator light (page 2-550).
Step 3.
Check light lead (10) for cracks, breaks, and corrosion.
a.
If light lead (10) is cracked or broken, replace it and install indicator light (page 2-550).
b.
If light lead (10) is corroded, clean using fine abrasive paper (item 20, Appendix C). Install
indicator light (page 2-550).
c.
If light lead (10) is not cracked, broken, or corroded, repair pink wire in cowl wiring harness
(page 2-137). Install indicator light (page 2-436).
TA242749
2-87